Skip to content
become a verified vendor

Coverage

Precast Industries — Everything Precast
Precast/Prestressed Concrete InstituteNational Precast Concrete AssociationAmerican Concrete Pipe AssociationConcrete Masonry & Hardscapes AssociationNortheast Precast Concrete AssociationPacific Northwest Precast Concrete AssociationCalifornia Precast Concrete AssociationTexas Concrete Products AssociationOhio Precast Concrete AssociationPrecast Concrete Association of New YorkNew Jersey Precast Concrete AssociationPennsylvania Precast AssociationPennsylvania Aggregates and Concrete AssociationPrecast Concrete Association of VirginiaPrecast Tank Association of VirginiaWisconsin Precast Concrete AssociationMichigan Concrete AssociationKentucky Concrete AssociationAlabama Concrete Industries AssociationFlorida Concrete & Products AssociationFlorida Prestressed Concrete AssociationPrecast Concrete Structures Association of FloridaCarolinas Concrete Pipe and Products AssociationPCI Georgia/CarolinasPrecast of MaineCAPCA PrecastAPAPrecast/Prestressed Concrete InstituteNational Precast Concrete AssociationAmerican Concrete Pipe AssociationConcrete Masonry & Hardscapes AssociationNortheast Precast Concrete AssociationPacific Northwest Precast Concrete AssociationCalifornia Precast Concrete AssociationTexas Concrete Products AssociationOhio Precast Concrete AssociationPrecast Concrete Association of New YorkNew Jersey Precast Concrete AssociationPennsylvania Precast AssociationPennsylvania Aggregates and Concrete AssociationPrecast Concrete Association of VirginiaPrecast Tank Association of VirginiaWisconsin Precast Concrete AssociationMichigan Concrete AssociationKentucky Concrete AssociationAlabama Concrete Industries AssociationFlorida Concrete & Products AssociationFlorida Prestressed Concrete AssociationPrecast Concrete Structures Association of FloridaCarolinas Concrete Pipe and Products AssociationPCI Georgia/CarolinasPrecast of MaineCAPCA PrecastAPA
Water Structures

Septic tank 3000 gal

Two-compartment monolithic septic tank with cast-in inlet and outlet tees, watertight to ASTM C1227.

Standard
ASTM C1227
Load class
H-20
Lead time
9 working days
Price
$2,180.00
Ø600 riser rings of the type fitted to the tank access openingsVerified listing1 / 5

Specification

Capacity
3000 US gal
Compartments
2
Wall thickness
100 mm
Access
2 × Ø600 risers
Watertightness
Vacuum tested
Burial depth
up to 1.5 m

Attached documents

Free to download. No email wall on technical data.

One pour, two compartments.

A 3000 US gallon two-compartment septic tank cast monolithically, with inlet and outlet tees cast in and watertightness verified to ASTM C1227.

  • Monolithic body — The tank is cast in one piece rather than assembled from a base and barrel, so there is no horizontal joint below liquid level.
  • Two compartments — A cast dividing wall separates the two compartments, with the transfer set at the design liquid level.
  • Cast-in tees — Inlet and outlet tees are cast in rather than fitted after stripping, fixing their level relative to the tank.
  • Vacuum tested — Watertightness is vacuum tested, with the test report issued as part of the document set.

Access risers

Two Ø600 risers give access to both compartments. They are brought up to finished level to suit a burial depth of up to 1.5 m.

Supplied from stock

Finished tanks are held in the yard, which is what supports the nine working day lead time.

In use

Where a 3000 gallon two-compartment tank is installed and what sits with it.

Domestic installations

Buried to a maximum depth of 1.5 m, rated H-20 for the cover and access arrangement.

Access and maintenance

Two Ø600 risers bring both compartments up to grade for inspection and pumping out.

Plant production

Cast in the plant's water structures bay and vacuum tested before it leaves.

FAQs

By vacuum test, with the result recorded in the watertightness report supplied with the tank.

Up to 1.5 m, at H-20 load class. Risers are brought up to suit the finished level.

Yes, the body is monolithic. There is no horizontal joint in the wall below liquid level.

They are cast in as part of the pour, so their levels are fixed relative to the tank rather than set on site.

Two Ø600 risers, one to each compartment.