Skip to content
become a verified vendor

Coverage

Precast Industries — Everything Precast
Precast/Prestressed Concrete InstituteNational Precast Concrete AssociationAmerican Concrete Pipe AssociationConcrete Masonry & Hardscapes AssociationNortheast Precast Concrete AssociationPacific Northwest Precast Concrete AssociationCalifornia Precast Concrete AssociationTexas Concrete Products AssociationOhio Precast Concrete AssociationPrecast Concrete Association of New YorkNew Jersey Precast Concrete AssociationPennsylvania Precast AssociationPennsylvania Aggregates and Concrete AssociationPrecast Concrete Association of VirginiaPrecast Tank Association of VirginiaWisconsin Precast Concrete AssociationMichigan Concrete AssociationKentucky Concrete AssociationAlabama Concrete Industries AssociationFlorida Concrete & Products AssociationFlorida Prestressed Concrete AssociationPrecast Concrete Structures Association of FloridaCarolinas Concrete Pipe and Products AssociationPCI Georgia/CarolinasPrecast of MaineCAPCA PrecastAPAPrecast/Prestressed Concrete InstituteNational Precast Concrete AssociationAmerican Concrete Pipe AssociationConcrete Masonry & Hardscapes AssociationNortheast Precast Concrete AssociationPacific Northwest Precast Concrete AssociationCalifornia Precast Concrete AssociationTexas Concrete Products AssociationOhio Precast Concrete AssociationPrecast Concrete Association of New YorkNew Jersey Precast Concrete AssociationPennsylvania Precast AssociationPennsylvania Aggregates and Concrete AssociationPrecast Concrete Association of VirginiaPrecast Tank Association of VirginiaWisconsin Precast Concrete AssociationMichigan Concrete AssociationKentucky Concrete AssociationAlabama Concrete Industries AssociationFlorida Concrete & Products AssociationFlorida Prestressed Concrete AssociationPrecast Concrete Structures Association of FloridaCarolinas Concrete Pipe and Products AssociationPCI Georgia/CarolinasPrecast of MaineCAPCA PrecastAPA
Beams & Columns

Prestressed girder 32 m

Post-tensioned I-girder for a 32 m clear span, cast in a match-cast bed with full documentation to AASHTO and state DOT references.

Standard
AASHTO LRFD / PCI MNL-116
Load class
HL-93
Lead time
42 working days
Price
On request
Aerial view of the plant, showing the long casting bays used for girder productionVerified listing1 / 4

Specification

Span
32.0 m
Depth
1800 mm
Web thickness
200 mm
Strand
19T13 × 4 ducts
Concrete
M50
Camber at transfer
38 mm

Attached documents

Free to download. No email wall on technical data.

Match-cast for a 32 metre clear span.

A post-tensioned I-girder for a 32 m clear span at 1800 mm depth, cast in a match-cast bed with documentation to AASHTO LRFD and PCI MNL-116.

  • Post-tensioned — Four ducts carrying 19T13 strand, stressed after the concrete has gained strength rather than pretensioned on a bed.
  • Match-cast bed — Cast in a match-cast bed so the girder geometry is held against the adjoining segment rather than set independently.
  • Documented to HL-93 — Supplied with the PT calculation, cube test results and method statement against HL-93 loading.
  • Camber recorded — Camber at transfer is 38 mm, recorded so bearing and deck levels can be set against the actual value.

Mix supply

M50 is batched to the pour. Cube results are recorded per pour and issued with the girder, since stressing cannot start until the concrete has reached strength.

Storage before despatch

Girders are stored on supports at the bearing positions so the section is not carried on a point it was not designed for.

In use

Where a 32 m post-tensioned girder is produced and placed.

Bridge spans

Set on bearings to carry a 32.0 m clear span at HL-93 loading.

Long-bed production

Cast in a match-cast bed long enough to hold the full span in one piece.

Yard storage

Supported at the bearing points while waiting for despatch, with the 42 working day lead time set by the casting and stressing cycle.

FAQs

Post-tensioned, with 19T13 strand in four ducts stressed after the concrete has gained strength.

38 mm at transfer. The value is recorded per girder so deck and bearing levels can be set against it.

Girder drawing, PT calculation, cube test results and a method statement, referenced to AASHTO LRFD and PCI MNL-116.

The girder occupies a match-cast bed through casting, strength gain and stressing before it can be moved.

HL-93, at a 32.0 m span and 1800 mm section depth.