Skip to content
become a verified vendor

Coverage

Precast Industries — Everything Precast
Precast/Prestressed Concrete InstituteNational Precast Concrete AssociationAmerican Concrete Pipe AssociationConcrete Masonry & Hardscapes AssociationNortheast Precast Concrete AssociationPacific Northwest Precast Concrete AssociationCalifornia Precast Concrete AssociationTexas Concrete Products AssociationOhio Precast Concrete AssociationPrecast Concrete Association of New YorkNew Jersey Precast Concrete AssociationPennsylvania Precast AssociationPennsylvania Aggregates and Concrete AssociationPrecast Concrete Association of VirginiaPrecast Tank Association of VirginiaWisconsin Precast Concrete AssociationMichigan Concrete AssociationKentucky Concrete AssociationAlabama Concrete Industries AssociationFlorida Concrete & Products AssociationFlorida Prestressed Concrete AssociationPrecast Concrete Structures Association of FloridaCarolinas Concrete Pipe and Products AssociationPCI Georgia/CarolinasPrecast of MaineCAPCA PrecastAPAPrecast/Prestressed Concrete InstituteNational Precast Concrete AssociationAmerican Concrete Pipe AssociationConcrete Masonry & Hardscapes AssociationNortheast Precast Concrete AssociationPacific Northwest Precast Concrete AssociationCalifornia Precast Concrete AssociationTexas Concrete Products AssociationOhio Precast Concrete AssociationPrecast Concrete Association of New YorkNew Jersey Precast Concrete AssociationPennsylvania Precast AssociationPennsylvania Aggregates and Concrete AssociationPrecast Concrete Association of VirginiaPrecast Tank Association of VirginiaWisconsin Precast Concrete AssociationMichigan Concrete AssociationKentucky Concrete AssociationAlabama Concrete Industries AssociationFlorida Concrete & Products AssociationFlorida Prestressed Concrete AssociationPrecast Concrete Structures Association of FloridaCarolinas Concrete Pipe and Products AssociationPCI Georgia/CarolinasPrecast of MaineCAPCA PrecastAPA
Water Structures

Utility vault 3 × 2 m

Traffic-rated cable vault with cast-in pulling irons, cable racks and a bolt-down aluminium hatch.

Standard
ASTM C858
Load class
H-20
Lead time
14 working days
Price
$4,650.00
Precast wall panels stored upright, of the type forming the vault wallsVerified listing1 / 5

Specification

Internal size
3000 × 2000 mm
Internal height
2100 mm
Wall thickness
150 mm
Hatch
1200 × 900 aluminium
Pulling irons
4 × 20 kN
Cable racks
6 positions

Attached documents

Free to download. No email wall on technical data.

A vault rated for the road above it.

A 3000 × 2000 mm traffic-rated cable vault at 2100 mm internal height, with cast-in pulling irons, cable racks and a bolt-down aluminium hatch.

  • Traffic rated — Rated H-20 to ASTM C858, so the vault can sit under a trafficked surface rather than in a verge only.
  • Cast-in pulling irons — Four pulling irons at 20 kN are cast into the structure, positioned to pull cable through the vault.
  • Cable racks — Six rack positions are fitted for supporting and separating cable runs inside the chamber.
  • Bolt-down hatch — A 1200 × 900 aluminium hatch bolts down, giving secured access at the 2100 mm internal height.

Cast on the plant floor

Produced in steel frames alongside the plant's panel work, which is what holds the internal dimensions across a batch.

Stored before despatch

Finished vaults are held in the yard with the hatch fitted, ready to load on a fourteen working day lead time.

In use

Where a 3 × 2 m cable vault is installed and what it carries.

Under trafficked surfaces

Set below a road or hardstanding at H-20 loading, with the hatch brought up to finished level.

Cable pulling and support

Four 20 kN pulling irons and six rack positions handle pulling the run in and supporting it afterwards.

Plant production

Cast at the plant in steel frames and stored complete with fittings.

FAQs

Yes, it is rated H-20 to ASTM C858, with a load rating document supplied.

Four irons at 20 kN each, cast into the structure rather than fixed after stripping.

1200 × 900 mm in aluminium, bolted down.

Six positions, for supporting and separating the cable runs inside the vault.

3000 × 2000 mm on plan at 2100 mm internal height, with 150 mm walls.