Skip to content
become a verified vendor

Coverage

Precast Industries — Everything Precast
Precast/Prestressed Concrete InstituteNational Precast Concrete AssociationAmerican Concrete Pipe AssociationConcrete Masonry & Hardscapes AssociationNortheast Precast Concrete AssociationPacific Northwest Precast Concrete AssociationCalifornia Precast Concrete AssociationTexas Concrete Products AssociationOhio Precast Concrete AssociationPrecast Concrete Association of New YorkNew Jersey Precast Concrete AssociationPennsylvania Precast AssociationPennsylvania Aggregates and Concrete AssociationPrecast Concrete Association of VirginiaPrecast Tank Association of VirginiaWisconsin Precast Concrete AssociationMichigan Concrete AssociationKentucky Concrete AssociationAlabama Concrete Industries AssociationFlorida Concrete & Products AssociationFlorida Prestressed Concrete AssociationPrecast Concrete Structures Association of FloridaCarolinas Concrete Pipe and Products AssociationPCI Georgia/CarolinasPrecast of MaineCAPCA PrecastAPAPrecast/Prestressed Concrete InstituteNational Precast Concrete AssociationAmerican Concrete Pipe AssociationConcrete Masonry & Hardscapes AssociationNortheast Precast Concrete AssociationPacific Northwest Precast Concrete AssociationCalifornia Precast Concrete AssociationTexas Concrete Products AssociationOhio Precast Concrete AssociationPrecast Concrete Association of New YorkNew Jersey Precast Concrete AssociationPennsylvania Precast AssociationPennsylvania Aggregates and Concrete AssociationPrecast Concrete Association of VirginiaPrecast Tank Association of VirginiaWisconsin Precast Concrete AssociationMichigan Concrete AssociationKentucky Concrete AssociationAlabama Concrete Industries AssociationFlorida Concrete & Products AssociationFlorida Prestressed Concrete AssociationPrecast Concrete Structures Association of FloridaCarolinas Concrete Pipe and Products AssociationPCI Georgia/CarolinasPrecast of MaineCAPCA PrecastAPA
Curing & Finishing

Vapour curing chamber

Insulated curing chamber with steam generator, programmable ramp control and data logging for 24 pallets.

Condition
Surplus
Year
2022
Usage
New surplus
Price
$54,000
Production hall interior of the type a curing chamber is installed inVerified listing1 / 3

Specification

Capacity
24 pallets
Steam output
600 kg/h
Ramp control
Programmable
Logging
Per-batch CSV
Insulation
100 mm PIR

What inspection covers

  • Photographs of every wear surface
  • Measured condition of key components
  • Operating record where the machine runs
  • An honest note on anything rebuilt

Twenty-four pallets, logged per batch.

An insulated vapour curing chamber for 24 pallets, with a 600 kg/h steam generator, programmable ramp control and per-batch data logging. New surplus.

  • 24 pallet capacity — The chamber holds twenty-four pallets, sized to buffer a production line between casting and demoulding.
  • Programmable ramp — Ramp control is programmable, so the temperature rise and hold can be set to the mix rather than run flat out.
  • Per-batch logging — Each batch is logged to CSV, giving a record of the cure against the units produced in it.
  • 100 mm PIR — Insulated with 100 mm PIR, with a steam output of 600 kg/h.

Cure control

A programmable ramp with logging means the cure applied to a batch can be shown afterwards, not just asserted.

Condition

Listed as new surplus from 2022 — built and not put into service, rather than used and resold.

In use

What the chamber is installed alongside and what it is for.

Line curing

Buffering twenty-four pallets between the casting and demoulding stations of a production line.

Production halls

Installed within the production building, insulated to 100 mm PIR against the surrounding space.

Quality records

Per-batch CSV logs give a cure record that can be filed against the units produced.

FAQs

The chamber was built in 2022 and not put into service. It is not a used machine being resold.

Twenty-four.

Yes, ramp control is programmable rather than fixed.

Each batch is logged to CSV, so the applied cycle can be retrieved later.

600 kg/h from the integral steam generator.